BZPJZ - NICKEL CADMIUM SEALED CELL BATTERY

Product Identification

Product ID:NICKEL CADMIUM SEALED CELL BATTERY
MSDS Date:10/03/1994
FSC:6140
NIIN:01-056-5321
MSDS Number: BZPJZ

Responsible Party
SAFT AMERICA INC, POWER SOURCES DIV
711 INDUSTRIAL BLVD
VALDOSTA, GA 31603
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 912-247-2331/ FAX 912-245-2880

Cage: 09052

Contractor
SAFT AMERICA INC.
1886 VALDOSTA, GA 31602 US

Telephone: 912-247-2331

Cage: 09052

Ingredients

CADMIUM (SARA 313) (CERCLA), % TOTAL OF INGREDS #1, 2, 3.

CAS: 7440-43-9

RTECS: EU9800000

Fraction By Weight: 17%

OSHA PEL 0.2 MG/M3 DUST; Z-2

ACGIH TLV: 0.01 MG/M3 DUST;9596

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


CADMIUM HYDROXIDE

CAS: 21041-95-2

Fraction By Weight: SEE #1%

OSHA PEL 0.05 MG CD/M3

ACGIH TLV: 0.05 MG CD/M3


CADMIUM OXIDE (SARA 302/313) (CERCLA)

CAS: 1306-19-0

RTECS: EV1925000

Fraction By Weight: SEE #1%

OSHA PEL 0.2 MG (CD)/M3 DUST

ACGIH TLV: 0.01 MG(CD)/M3; 9596


NICKEL (SARA 313) (CERCLA), % FOR TOTAL OF INGREDS 4,5,6.

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 19%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9596


NICKEL HYDROXIDE (SARA 313) (CERCLA)

CAS: 12054-48-7

RTECS: QR7040000

Fraction By Weight: SEE #4%

OSHA PEL 1 MG(NI)/M3

ACGIH TLV: 0.1 MG(NI)/M3; 9596

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


NICKEL OXIDE

CAS: 1313-99-1

RTECS: QR8400000

Fraction By Weight: SEE #4%

OSHA PEL 1 MG/M3 AS NI

ACGIH TLV: 1 MG/M3 AS NI


POTASSIUM HYDROXIDE (CERCLA)

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 85 - 90%

OSHA PEL C 2 MG/M3

ACGIH TLV: C 2 MG/M3; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


AS COBALT METAL (SARA 313), COBALT HYDROXIDE

CAS: 7440-48-4

RTECS: GF8750000

Fraction By Weight: 1%

OSHA PEL 0.1 MG/M3

ACGIH TLV: 0.02 MG/M3; A3; 9596

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:EYE:FIRE/CELL RUPTURE OCCURS
ELECTROLYTE SOLN INSIDE BATT EXTREMELY CORR TO EYE TISSUES.MAY
RESULT IN PERM BLINDNESS.CONTACT W/NIO MAY CAUSE MINOR
IRRIT.SKIN:CONTACT W/ELECTROLYTE SOLN MAY CAUSE SER B URNS.CONTACT
W/NI CMPDS MAY CAUSE SKIN SENS,RESULT IN CHRONIC ECZEMA/NI
ITCH.INGEST:ELECTROLYTE SOLN CAUSES TISSUE(SUPP)
Explanation of Carcinogenicity:CONTAINS NICKEL & CADIUM COMPOUNDS. PER
MSDS:NIOSH RECOMMENDS THAT NI & CD BE TREATED AS OCCUPATIONAL
CARCINOGENS.
Effects of Overexposure:CORR TO EYE TISSUES,PERM BLINDNESS,MIONOR
IRRIT.SERIOUS SKIN BURNS,SENS,CHRONIC ECZEMA,NI ITCH.DMAG TO THROAT
AREA & GASTRO/RESP TRACT,NAU,INTESTINAL DISORDERS.MILD NASAL MUC
MEMBRANES IRRIT TO DMG OF LUNG TISSUES PROPER.DRY
THROAT,COUGH,HEADACHE,VOMIT,CHEST PAINS,CHILLS,PULM EDEMA,BREATH
DIFF,PROSTRATION,KIDNEY DMG.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE:FLUSH W/LOTS OF WATER @LEAST 15MINS IF ABUSE CAUSES SAFTY
VENTS TO ACTIVATE.GET IMMED MED ATTN.SKIN:REMOVE CONTAMIN
CLOTH.FLUSH W/LOTS OF WATER @LEAST 15MINS.WASH
W/SOAP/WATER.INGEST:DO NOT INDUCE VOMIT.DILUTE BY GIVING WATER.IF
AVAILABLE GIVE SEVERAL GLASSES OF MILK.GET IMMED MED ATTN.DO NOT
GIVE ANYTHING BY MOUTH IF UNCONSC.INHAL:REMOVE TO FRESH AIR.GIVE
OXY/ART RESP IF NEED.GET MED ATTN IMM

Fire Fighting

Flash Point:NP FOR ITEM
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NP
Upper Limits:NP
Extinguishing Media:CO2, SAND.
Fire Fighting Procedures:USE SCBA TO AVOID BREATH TOXIC FUMES.WEAR
PROTECTIVE CLOTHING/EQPMT TO PREVENT POTENTIAL BODY CONTACT
W/ELECTROLYTE SOLN OR MIXTURE OF WATER & SOLN.
Unusual Fire/Explosion Hazard:ELECTRO SOLN CORR TO ALL HUMAN
TISSUES.WILL RX VIOLENTLY W/MANY ORG CHEM ESPECIALLY
NITROCARBONS/CHLOROCARBONS.ALSO RXS W/ZN.AL,SN,ACTIVE MATLS-RELEASE
FLAMM H2

Accidental Release

Spill Release Procedures:ELECTROLYTE SPILLS:FLUSH W/WATER & NEUTRALIZE
W/DILUTE CITRIC ACID.
Neutralizing Agent:ELECTROLYTE:NEUTRALIZE W/DILUTE CITRIC ACID.

Handling

Handling and Storage Precautions:IN CASE OF FIRE DON'T BREATH
SMOKE/FUME.THESE CELLS/BATT CONSTRUCTED FROM THEM MAY BE HIGHLY
CHARGE/CAPABLE OF HI ENERGY DISCHARGE.DON;T BREAK OPN CEL
Other Precautions:CARE SHOULD BE TAKEN IN HNDL CELLS PROPERLY TO AVOID
SHORTING/MISUSE THAT WILL RESULT IN RAPID UNCONTROLLED
ELECTRICAL/CHEM/HEAT ENERGY RELEASE.DO NOT SHORT CIRCUIT-MAY CAUSE
BURNS.DO NOT ALLOW FLAMES /SPARK TO COME NEAR CELLS.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR IF CELL
BROKEN OPN DURING FIRE TO MAINTAIN EXPO LEVELS BEL TWA FOR CADMIUM
& NICKEL COMPOUNDS.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:WATER-INSOLUBLE,NON-PERM GLOVE(SYN RUBB)
Eye Protection:SPLASH GOGGLES, FACE SHIELDS.
Other Protective Equipment:DO NOT USE LEATHER OR WOOL GLOVES.RUBBER
APRON OR EQUIVALENT IF EXPO TO ELECTROLYTE SOLN IS LIKELY.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HEALTH HAZ:DMG TO THROAT AREA/GASTRO/RESP TRACT.NI CMPDS
INGEST:NAU/INTESTINAL DISORDER.INHAL:NO EXPO EXCEPT IN CASE OF
FIRE/ABUSE.CD &/OR NI CMPD:VARY FRM MILD NASAL MUC MEMB IRRIT TO
LUNG TISSUES PR OPER DMG.CDO MAY CAUSE DRY
THROAT,COUGH,HEAD,VOMIT,CHEST PAIN,CHILLS.CHRONIC:PULM EDEMA,BREATH
DIFFI,PROSTRATION,KID DMG

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:NA
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:NA
Vapor Density:NA
Spec Gravity:1.17-1.25 ELECT
pH:NP
Viscosity:NP
Evaporation Rate & Reference:NOT DETERMINED
Solubility in Water:ELECT SOLUBLE.
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:NP
Corrosion Rate:NP

Stability

AL,ZN,SN,OTHER ACTIVE METALS;ACID;CHLORINATED & AROMATIC
HYDROCARBONS;NITROCARBONS;HALOCARBONS.
Stability Condition to Avoid:CADIUM FUMES MAY BE RELEASED WHEN BATT ARE
SUBJ TO HIGH TEMPERATURES.
Hazardous Decomposition Products:NICKEL OXIDE, CADMIUN, CADMIUN OXIDE,
POTASSIUM HYDROXIDE.

Disposal

Waste Disposal Methods:STORAGE BATT IS HAZ WASTE UNDER RCRA.IT MAY BE
RETURNED TO SAFT FOR RECYCLING.BATT IS TCLP TOXIC.BATT/ELECTRO SOLN
ARE CORR.IF NOT RECYLCED MUST BE DISPOSED OF IAW ALL FED/STATE/LOC
REGS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.